Panels
Dean Steel Buildings holds Underwriter Laboratory and South Florida Building Code compliance on their panels.
Panel Part Numbers
RTA6-200406
RT Panel Type:
PS = PRO SEAM
RT = RIB TWELVE
RS = RIB SIX
SP = SHADOW PANEL
FS = FLAT STOCKA For PS:
A= 12" wide
B= 18" wide
C= 24" wideFor RT, RS, SP:
A= Standard
B= Left Miter
C= Right Miter
H= UL 906 Gauge ( 4 - 24 GA, 6 - 26 GA) - Miter or Pitch Code * 20 Length in feet 04 Length in inches 06 Length in sixteenth inches
* Miter or Slope Code
A 0:12 J 4:12 B 0.5:12 K 4.5:12 C 1:12 L 5:12 D 1.5:12 M 5.5:12 E 2:12 N 6:12 F 2.5:12 X SPECIAL Note: Dimension for Miter panels should be the overall length. Miter panels available only for RT and SP type panels.
36" Ribbed Panels
Note: Rib Six panel (RS) not shown
but is also available.
![]()
RIB TWELVE SHADOW PANELRibbed Panels are available in Galvalume™, both in 24 and 26 GA (80,000psi Yield), and in different colors (See Color Selection for availability). Special colors (may require minimum order) are also available.
Ribbed Panels notes:
1. Panels sold as component parts carry no finish guarantees.
2. Squares are net coverage on width of 36". Figure end laps as required.
3. Panels with purlin bearing leg are available in Rib-12 Galvalume™.
4. Panel availability subject to change without notice. Check with your Estimator for current availability.
Pro Seam Panels
PANEL AVAILABILITY
WGT/SQ 26 GA GLM 92.6 24 GA GLM 118.1 24 GA WHT 127.9 Pro Seam notes:
1. Pro Seam panels have limited color selections; Non-stock color requires 200sq. minimum order.
2. All panels are factory notched at both ends.
3. Oil canning is not a cause for rejection.
4. Tools required: Spacer tool (HW9051), shaping tool (HW9052).
5. See our Pro Seam Requirements for important ordering information.
6. Export available. Please call your Estimator for more information
Pro Seam Accessories
(For Rib-12 panels accessories please see Flashing and Hardware)
Part No.
Finish Length/Size Weight (lbs)
LOW FIXED CLIPHW9062 Silver 3-3/8" .13
HIGH FIXED CLIPHW9063 Silver 4-3/8" .16
LOW FLOATING CLIPHW9064 Red 3-3/8" .97
HIGH FLOATING CLIPHW9065 Red 4-3/8" 1.1
UTILITY CLIPHW9066 Silver 3" .12
LOW EAVE PLATEAN1276 GNZ 4'-0" 3.7
HIGH EAVE PLATEAN1277 GNZ 4'-0" 4.7
LOW FIXED RAKE SUPPORTAN1271 Red 10'-0" 13.7
LOW FLOATING RAKE SUPPORTAN1272 Red 20'-0" 20.9
HIGH FIXED RAKE SUPPORTAN1273 Red 10'-0" 16.0
HIGH FLOATING RAKE SUPPORTAN1274 Red 20'-0" 24.8
BACK-UP PLATE
FOR USE AT ENDLAPS AND AT RIDGE, USE OVER PLYWOOD DECK.HW9103 Red 24" 3.18 HW9106 Red 18" 2.47 HW9109 Red 12" 1.77 HW9112 Red 24" 3.18
CINCH STRAP
FOR USE AT ENDLAPS TO COMPLETE THE COMPRESSION JOINT.HW9104 GLM 24" .71 HW9104 COL 24" .71 HW9107 GLM 18" .57 HW9107 COL 18" .57 HW9110 GLM 12" .42 HW9110 COL 12" .42
OUTSIDE CLOSURE
24 GA METAL - FOR USE AT RIDGE, ROOF PENETRATIONS, ETC.HW9105 GLM 24" .81 HW9105 COL 24" .81 HW9108 GLM 18" .65 HW9108 COL 18" .65 HW9111 GLM 12" .49 HW9111 COL 12" .49
INSIDE CLOSURE
METAL FOR EXTENDED LIFEHW9048 GLM .22 HW9048 COL .22
THERMAL SPACER
POLYSTYRENE BLOCK USED TO INCREASE THE INSULATION CAPACITY ALONG THE PURLINS. (WITH HIGH SYSTEM ONLY)HW9049 - 3"x1"x23-7/8"
(use with 2"-3" ins).09 HW9114 - 3"x5/8"x23-7/8"
(use with 4"-5" ins).03 HW9115 - 3"x3/8"x23-7/8"
(use with 6" ins).05
SPLICE TAPE SEALER
A 100% SOLIDS, BUTYL BASED ELASTOMERIC MATERIALHW9050 - 1-5/8"x1/8"x30' 2.3
TAPE SEALERHW5775 - 1/2"x3/32"x45' 1.4 HW5721 - 7/8"x3/16"x25' .8
MINOR RIB TAPE SEALERHW9113 - 1-3/8"x7/32"x4" .07
GUTTER SEALHW5720 CLR 10.6 oz .7
SPACER TOOL
FOR MAINTAINING PANEL MODULEHW9021 PVC 24" 2
SHAPING TOOLHW9052 PVC 3'x6" 5
SELF-DRILLER
PLATED STEELHW9053 GNZ/COL 1/4"-14x1-1/4" Tek®/2
5/16" hex, no washer closures
Purlin bracing to purlin
Rake angle to purlin
Eave Plate to eave strut
Optional clip fastener (Non-UL 90) 2000/CTN40/CTN
SELF-DRILLER
W/SHOULDER PLATED STEELHW9054 GNZ 1/4"-14x1-1/4" Shoulder Tek®/2
5/16" hex head, no washer. Floating rake support to rake angle. 2500/CTN40/CTN
SELF-DRILLER
PLATED STEELHW9055 GNZ/COL 1/4"-14x1-1/4" Tek®/2
5/16" hex head with washer. Optional exterior fastener. UL90 Clip to purlin. 2000/CNT40/CTN
SELF-DRILLER
PLATED STEELHW9061 GNZ #12-24x1-1/4" Tek®/4
5/16" hex head with washer. Clip to bar joist fastener. Rake angle to joists. 2500/CTN68/CTN
SELF-DRILLER
ZAC®HW9057 GNZ/COL 1/4"-14x1-1/4" ZAC®
3/8" hex head with washer. Long life exterior fastener. Light gauge to heavy gauge. 2000/CTN75/CTN
SELF-TAPPER
ZAC®HW5502 GNZ/COL #14x3/4" ZAC®
3/8" hex head with washer. Long life exterior fastener. Light gauge to light gauge. 2000/CTN60/CTN
PRO SEAM RIDGE FLASHINGFRC6-100200 GLM/COL 10'-2" 24.5 FL4410
for Ridge Cap closureGLM/COL .32
RIDGE SUPPORT ANGLEANB4C020400
9" MonoventGNZ 2'-4" 1.97 ANB4C021002
12 " MonoventGNZ 2'-10 1/8" 2.4
PRO SEAM GUTTET BRACKET
FIELD ASSEMBLY REQUIRED; FASTENER NOT INCLUDEDHW5647 GNZ 1:12 .6 HW5648 GNZ 4:12 .6
BRACING STRAPAN1265 Varies 1-1/2"x100' roll 14 AN1267 Varies 1-1/2"x25' roll 3.5
VARIABLE TERMINATION TRIMFTP6-100200 GLM/COL 10'-2" 19.5 FTP4-100200 GLM/COL 10'-2" 19.5
PRO SEAM RAKE TRIMFRP6-100200 GLM/COL 10'-2" 19.5 FRP4-100200 GLM/COL 10'-2" 19.5
PEAK BOXFNP-010500
Need Slope CodeGLM/COL 1'-5" 1.7
HIGH SIDE SCULPTURED EAVE FLASHINGFEH6-100200 GLM/COL 10'-2" 19.5
SCULPTURED GUTTER ENDFL4204 COL RH .5 FL4205 COL LH .5
PRO SEAM EAVE FLASHINGFEP6-100200
( "-" For slope Code)GLM/COL 10'-2" 4.9
GUTTERGUA6-200700 COL 20'-7" 29.7 GUA4-200700 COL 20'-7" 38
RAKE SLIDEFRS6-100200 COL 10'-2" 3.7
SCULPTURED RAKE TRIM END CAPFL4217 COL RH .6 FL4218 COL LH .6